Case Planning:
- It is suggested that study models be sent to Aurum Ceramic/Classic
for pre-planning and computerized prosthesis design to determine rest
areas and any adjustments needed to dentition.
- Takes all the guesswork
out of the process and virtually eliminates adjustments.
- Doctor will
be provided with a duplicate model on which a survey and design has
been outlined with rest preparation suggestions highlighted
in a green colour. Doctor can request that a custom tray be provided
along with the survey and design recommendation.
Impression and Model Tips:
Master Impression
- Ensure that a full mouth impression is taken with all teeth
and anatomical landmarks reproduced.
- Impression must be fully
extended.
- If for an upper cast partial, make sure that the palate
is included in the impression.
- If for a lower cast partial, ensure
full extension of the impression including the retromolar pads.
Bite Registration
- Ensure bite registration is taken in centric.
Models:
- Die stone mixed with water (NO Hardener) is recommended in a
very thick, smooth mix. A thick mix will flow under vibration but
does not run like a thin mix. Thickly mixed, the model is harder
with less chance of air bubbles.
- Indication of correct thickness of
mixed stone: the mix does not drip or fall off when the spatula is
inverted.
- IMPORTANT: After the impression is poured, DO NOT invert
the tray onto a stone paddy. Inverting can cause error. The unset
stone will
try to sag away from the impression. The degree of sag (if it occurs)
will not be visible to the eye, but is sufficient to cause poor fit
of the framework. Instead, mound the thick stone on top of the tray
and allow it to set. Before pouring the model, place Playdoh (or
children’s modelling clay) in the tongue area of the lower
tray to keep the stone from locking over the lingual flange.
Preparation Requirements:
General Principles
- Proper tooth preparation is a must for a successful cast
partial restoration.
- Ensure there is adequate reduction for interocclusal
space (e.g., minimum 1 mm space for clasp clearance where frame crosses
dentition).
- If necessary, ensure there is adequate preparation for rests,
guide planes and interocclusal space as indicated by design.
- Guide planes
must be parallel and surfaces smooth to ensure easy insertion.
Adjustment
- Need for adjustment is rare. However, when necessary, use
Aurum Clasp Adjuster between the clasp and minor connector.
- DO NOT twist
the instrument and DO NOT use pliers.
- Gradually adjust the clasp step-by-step
until the retention is adequate.
Return
to Titanium Frameworks product page |