Shade Selection
Recommended Shade Guides: Vita Lumin Shade Guide.
Preparation
Tips
POSTERIOR PREPARATION
 |
Since the scanner's
tip is rounded, the finish line should be a chamfer placed subgingivally
at 0.5 to 0.7 mm. A rounded shoulder may also be an appropriate
design.
A relatively
level topography should be accomplished during preparation of the
occlusal surface of posterior dentition.
|
 |
The
occlusal surface of a posterior tooth is shaped, eliminating undercuts
and sharp edges. Steep slopes and sharp grooves are avoided to enable
the scanner to recognize all of the information provided through the
tip. |
ANTERIOR PREPARATION
 |
For
anterior dentition, preparation of the lingual surface requires shaping
with a diamond bur to provide space for crown contour and retention.
|
 |
Fine
finish lines on the prepared tooth enable the scanner to precisely
register all aspects of the die models, directly affecting the marginal
fit of the definitive restoration. |
PROCERAŽ
AllCeram Preparation Tips
John N. Nasedkin, DDS, MRCD (C)
As with any restoration,
proper and careful planning and preparation is the key to success. The
following tips are just some of the critical considerations that I have
found work well in my practice:
- Make your shade selection beforehand. Procera has a translucent substrate
that effectively blocks most tooth stains. The AllCeram porcelain is
high in chroma and gives particularly vital restorations.
- Make depth cuts with cylindrical diamonds on the facial surface of
upper anterior teeth in two planes - finish above the gingival tissues.
- Use a wheel-shaped or football diamond to reduce the lingual surface
of upper anteriors to insure adequate contour and reduction.
- When tooth loss is extensive, place directed shrinkage foundations
as a build-up and block out undercuts - use self-cure composite for
this purpose.
- Place a thin margin deflection thread and then finish with a Brasseler
8879 .014 or .012 diamond for the final marginal chamfer.
- Use the Flexible Clearance Gauge from Belle de St. Claire to insure
2 mm of occlusal clearance.
- Make sure your preparations have rounded contours only, no sharp angles.
 |
|
 |
|
Two plane
proximal reduction with round-ended diamond to above gingival margin.
|
|
Finishing
step: thin deflection thread is placed in the gingival sulcus and
Brasseler finishing diamond 8879-014 is used to define the chamfer
margin.
|
 |
Refinement
of tooth preparation for Procera crown with Procera chamfer diamond.
NOTE: thin deflection cord in place. Finish with Brasseler 8879-014
fine diamond then place retraction thread. Remove retraction thread
prior to impression making.
|
- Shrink wrap the prepared teeth before or after the impression. Use
alcohol in a pellet and rub to remove the air-inhibited layer. The polymer
coating protects the tooth and reduces sensitivity. Take full arch impressions
of prepared teeth and of the opposing arch.
- Reline your provisional(s) for more accurate marginal fit. Use non-eugenol
temporary cement. This will mean fewer insertion problems.
- Allow additional time for laboratory fabrication - the process takes
longer than normal.
- When the prepared tooth is short and requires length extension, advise
your lab to wax the coping to full contour, cut-back by 1.25 and provide
an inside-outside scan to the processing facility in order to insure
that the porcelain is adequately supported.
- With root-filled teeth, use a quartz and carbon fibre post (such as
Aestheti-post) and tooth-colored core material.
 |
 |
|
Fractured
upper left central incisor.
|
Procera
crown at one year follow-up. |
Reprinted with
permission of Nobel Biocare. Procera is a registered trademark of Nobel
Biocare.
Return